01 · PRINSIP MASTER
Aturan pengembangan yang tidak boleh terputus
P-01TraceableSetiap hasil memiliki input, satuan, rumus, asumsi, sumber, dan interpretasi.
P-02RepeatableProyek dapat disimpan, dibuka, dihitung ulang, dan dibandingkan.
P-03ReviewableSetiap modul melewati range check, standar, koordinasi, dan persetujuan.
P-04ExtensibleFitur baru memakai kontrak modul yang sama dan tidak mengubah rumus lama tanpa versi.
02 · FLOW INDUK
Alur satu proyek dari data sampai persetujuan
01
Identitas & Data Bangunan
Identitas & Data Bangunan
02
Bab I Lift & Eskalator
Bab I Lift & Eskalator
03
Bab II Pompa & Hidran
Bab II Pompa & Hidran
04
Bab III Genset
Bab III Genset
05
Bab IV Air Conditioning
Bab IV Air Conditioning
06
Integrasi, BOQ, RAB, AI, Laporan
Integrasi, BOQ, RAB, AI, Laporan
03 · STRUKTUR BUKU
Empat bab menjadi tulang punggung digitalisasi
BAB ILift & Eskalator
- Waiting time dan handling capacity
- Round trip time dan beban puncak
- Zoning, skylobby, hoistway
- Daya, efisiensi, lift hidrolik
- Kapasitas dan daya eskalator
BAB IIPompa & Hidran
- Head, losses, Reynolds, NPSH
- Daya, efisiensi, kavitasi
- Jenis, impeller, tingkat, material
- Debit, reservoir, fire pump
- Instalasi, warna, label, DED
BAB IIIGenset
- Daftar beban dan kapasitas
- Starting motor dan cadangan
- Tata letak, ventilasi, exhaust
- Suara, getaran, bahan bakar
- AMF, ATS, kontrol, maintenance
BAB IVAir Conditioning
- Kondisi desain dan psikrometrik
- Dinding, kaca, atap, lantai
- Penghuni, lampu, peralatan
- Ventilasi, infiltrasi, laten
- Sistem AC, duct, pipa, drainase
04 · REGISTRI MODUL
Status baseline master version 1.0
| ID | Modul | Mesin Hitung | Output | Status | Pengembangan Berikut |
|---|---|---|---|---|---|
| M01 | Lift & Eskalator | RTT, waiting, handling, peak | Hasil, review, BOQ, laporan | PARSIAL | Multizona, skylobby, hoistway, eskalator |
| M02 | Pompa | Head, losses, power, NPSH | Hasil, review, BOQ, laporan | AKTIF | Kurva, jenis, impeller, material, DED |
| M03 | Hidran | Debit, reservoir, TDH, pump | Hasil, review, BOQ, laporan | PARSIAL | Layout, jangkauan, label, FDC, DED |
| M04 | Plumbing | Demand, storage, transfer pump | Hasil, review, BOQ, laporan | AKTIF | Air kotor, hujan, sanitasi |
| M05 | Panel Listrik | Load, current, MCCB, cable, drop | Hasil, review, BOQ, laporan | AKTIF | Short circuit, selectivity, SLD |
| M06 | Genset | Demand, starting, kVA, selection | Hasil, review, BOQ, laporan | PARSIAL | Room, acoustic, exhaust, ATS/AMF |
| M07 | Air Conditioning | Cooling load, BTU/h, TR | Hasil, review, BOQ, laporan | PARSIAL | CLTD/RTS, latent, psychrometric, duct |
| X01 | AI Decision Support | Context, risks, standards, report | Findings dan action list | AKTIF | Integrasi LLM/API dan ekstraksi PDF |
05 · KONTRAK MODUL
Format wajib setiap fitur baru
Pipeline keluaran
Data masukanAsumsiTabel referensiRumusPerhitunganHasil & satuanRange checkInterpretasiTemuan AIAlternatifBOQ/RABLaporan
Kontrak data
{
"id": "Mxx",
"chapter": "Bab I-IV",
"title": "Nama modul",
"version": "major.minor.patch",
"inputs": [{"key":"...","unit":"...","source":"..."}],
"formulae": [{"id":"...","expression":"..."}],
"results": [{"key":"...","unit":"..."}],
"checks": [{"rule":"...","severity":"..."}],
"boq": [{"description":"...","qty":"...","unit":"..."}],
"references": [{"standard":"...","edition":"verify-latest"}]
}06 · ARSITEKTUR MASTER
Komponen yang harus dipertahankan
LAYER 1Project DataIdentitas, fungsi, lokasi, geometri, populasi, kondisi desain.
LAYER 2Calculation EnginesRumus deterministik, satuan, tabel, versi, dan pengujian.
LAYER 3Review & AIRange check, standar, risiko, koordinasi, rekomendasi.
LAYER 4DeliverablesDatabase, dashboard, BOQ, RAB, laporan, audit trail.
07 · ROADMAP TERKENDALI
Urutan pengembangan setelah master
| Prioritas | Paket | Target | Gate selesai |
|---|---|---|---|
| P1 | Digitalisasi Bab I | Semua subbab lift dan eskalator | 100% registry Bab I |
| P2 | Digitalisasi Bab II | Pompa, hidran, tabel, DED | 100% registry Bab II |
| P3 | Digitalisasi Bab III | Genset dan seluruh subsistem | 100% registry Bab III |
| P4 | Digitalisasi Bab IV | Cooling load dan pemilihan sistem | 100% registry Bab IV |
| P5 | Standar terbaru | Verifikasi SNI, PUIL, NFPA, ASHRAE | Matriks edisi dan pasal |
| P6 | AI generatif | API, ekstraksi PDF, RAG dokumen | Uji jawaban dan sumber |
08 · KONTROL VERSI
Master tidak boleh diubah tanpa rekaman
| Versi | 1.0.0 |
| Tanggal baseline | 06 Agustus 2026 |
| Pemilik program | Dr. Ir. An An Anisarida, S.T., M.T., IPM., ASEAN.Eng. |
| Status | Master aktif untuk pengembangan lanjutan |
| Aturan perubahan | Setiap perubahan mencantumkan modul, alasan, rumus terdampak, hasil pengujian, kompatibilitas, dan nomor versi. |